Beam Shear Capacity Calculator
Free Beam shear capacity Calculator for structural engineering projects. Enter dimensions to get material lists and cost estimates.
Beam Shear Capacity Calculator
Calculator
Adjust values & calculateEnter your values below. Every result is computed in your browser โ no data is sent to any server.
Formula: Vc = 2 * sqrt(fc) * bw * d | Vs = Av * fy * d / s | phi-Vn = 0.75 * (Vc + Vs)
Worked example โ Design shear capacity = 47.52 kips
Formula
Vc = 2 * sqrt(fc) * bw * d | Vs = Av * fy * d / s | phi-Vn = 0.75 * (Vc + Vs)
The concrete shear contribution Vc uses ACI 318 simplified method with 2*sqrt(fc)*bw*d. The steel stirrup contribution Vs depends on stirrup area, yield strength, effective depth, and spacing. The total nominal shear strength Vn is multiplied by the shear reduction factor phi of 0.75 to obtain the design capacity.
Worked Examples
Example 1: Typical Rectangular Beam
Problem:A 12-inch wide beam has an effective depth of 20 inches, concrete strength of 4000 psi, and No. 3 stirrups (Av = 0.22 sq in) at 8-inch spacing with fy = 60,000 psi.
Solution:Vc = 2 * sqrt(4000) * 12 * 20 = 30,358 lb = 30.36 kips Vs = 0.22 * 60000 * 20 / 8 = 33,000 lb = 33.00 kips Vn = 30.36 + 33.00 = 63.36 kips phi-Vn = 0.75 * 63.36 = 47.52 kips
Result:Design shear capacity = 47.52 kips
Example 2: Deep Beam with Close Stirrups
Problem:A 16-inch wide beam with d = 30 inches, fc = 5000 psi, No. 4 stirrups (Av = 0.40 sq in) at 6-inch spacing, fy = 60,000 psi.
Solution:Vc = 2 * sqrt(5000) * 16 * 30 = 67,882 lb = 67.88 kips Vs = 0.40 * 60000 * 30 / 6 = 120,000 lb = 120.00 kips phi-Vn = 0.75 * (67.88 + 120.00) = 140.91 kips
Result:Design shear capacity = 140.91 kips
Frequently Asked Questions
What is beam shear capacity and why does it matter?
Beam shear capacity is the maximum shear force a reinforced concrete beam can resist before failing in a diagonal tension mode. Shear failures are sudden and brittle, unlike flexural failures which show warning signs like cracking and deflection. The total shear capacity Vn equals the concrete contribution Vc plus the steel stirrup contribution Vs. Designing adequate shear reinforcement is critical for structural safety.
How is the concrete shear contribution Vc calculated?
According to ACI 318, the simplified concrete shear strength is Vc = 2 * sqrt(fc) * bw * d, where fc is the concrete compressive strength in psi, bw is the beam web width in inches, and d is the effective depth in inches. This formula assumes normal-weight concrete without axial load. The result is in pounds of force. For lightweight concrete, a lambda factor of 0.75 to 0.85 is applied as a multiplier.
What are stirrups and how do they resist shear?
Stirrups are U-shaped or closed-loop steel bars placed perpendicular to the longitudinal reinforcement in a beam. They intercept diagonal shear cracks and transfer the tensile forces across the crack back into the concrete. The steel shear contribution is Vs = Av * fy * d / s, where Av is the total cross-sectional area of stirrup legs, fy is the yield strength, d is the effective depth, and s is the center-to-center spacing of stirrups.
What is the phi factor for shear and why is it lower than for flexure?
The strength reduction factor phi for shear is 0.75 per ACI 318, compared to 0.90 for flexure in tension-controlled sections. This lower factor reflects the brittle nature of shear failures, which provide less warning before collapse. The design shear capacity phi-Vn must exceed the factored shear demand Vu at all critical sections. The critical section for shear is typically located at a distance d from the face of the support.
Why does the concrete shear contribution use the square root of the compressive strength?
Shear failure in a beam without stirrups is really a diagonal tension failure, and the tensile strength of concrete scales roughly with the square root of its compressive strength rather than linearly. That is why Vc is taken as two times the square root of f prime c times the web width times the effective depth. Doubling f prime c from 4,000 to 8,000 psi raises Vc by only about 41 percent, so a richer mix is an inefficient way to buy shear strength.
How does stirrup spacing change the steel contribution Vs?
Vs equals the area of shear reinforcement crossing a crack, times the yield strength, times the effective depth, divided by the spacing. Spacing sits in the denominator, so halving it doubles Vs. Codes also cap spacing at roughly half the effective depth, and tighter still at high shear demand, to guarantee that any diagonal crack is intersected by at least one stirrup rather than passing between them.
What is diagonal tension cracking and how does it form?
Where shear and bending act together, the principal tensile stress tilts away from horizontal, reaching about 45 degrees near the neutral axis close to the supports. Concrete cracks perpendicular to that tension, producing the characteristic inclined cracks in the shear span. Once cracked, the beam behaves like a truss with concrete struts in compression and stirrups acting as vertical tension ties, which is the model behind the Vc plus Vs approach.
What is the difference between one-way shear and two-way punching shear?
One-way shear is the beam action this calculation addresses, checked on a vertical section a distance d from the face of the support across the full web width. Two-way or punching shear applies to slabs and footings loaded by a column, where the failure surface is a cone around the load and the critical perimeter is taken a distance of d over two from the column face. The two checks use different critical sections and different capacity expressions.
When are minimum stirrups required even though the concrete alone appears adequate?
Codes generally require a minimum area of shear reinforcement wherever the factored shear exceeds half the reduced concrete capacity, well before the concrete contribution is exhausted. The reason is brittleness: an unreinforced web can fail suddenly once a diagonal crack forms, with no warning and no reserve. Minimum stirrups hold the crack closed, maintain aggregate interlock and convert a sudden failure into a ductile one.
Why is the effective depth d used instead of the overall beam height?
Effective depth is measured from the extreme compression fibre to the centroid of the longitudinal tension reinforcement, so it excludes the cover and the part of the section below that centroid. It represents the internal lever arm actually available to resist shear and moment. Using the full height overstates capacity, and the error grows on shallow beams where cover is a larger fraction of the section.
References
Background & Theory
History
Reviewed for accuracy by Abdullah, Technical Content Specialist ยท Editorial policy
Related Calculators
๐ Annual Planning & Capacity Aligner
Align annual OKRs with realistic engineering capacity accounting for maintenance and PTO
โ๏ธLegal Contract Capacity Planner
Estimate legal team capacity and contract turnaround time bottlenecks
๐ฎGame Server Capacity Planner
Estimate game server bandwidth and CPU requirements based on tick rate
๐ฅMedical Appointment Scheduling Capacity Planner
Calculate healthcare provider capacity and optimize appointment scheduling
๐บ๏ธSales Territory Capacity & Account Coverage Planner
Calculate optimal account distribution and rep capacity for territory planning
๐งฎBolt Shear Capacity Calculator
Calculate bolt shear capacity with inputs, formulas, and instant results.
๐งฎShear Wall Capacity Simplified Calculator
Calculate shear wall capacity simplified with inputs, formulas, and instant results.
๐งฎAcibeam Capacity Flexure Calculator
Calculate acibeam capacity flexure with inputs, formulas, and instant results.