Skip to main content

Transmission Loss Calculator

Our acoustic waves calculator computes transmission loss accurately. Enter measurements for results with formulas and error analysis.

Share this calculator

Formula

TL = 20 log10(pi m f / (rho_air c)) for normal incidence

Where TL is the transmission loss in decibels, m is the surface density (mass per unit area) in kg/m2, f is the frequency in Hz, rho_air is the air density (1.21 kg/m3), and c is the speed of sound (343 m/s). Field incidence TL is approximately 5 dB less than normal incidence.

Worked Examples

Example 1: Concrete Wall Transmission Loss

Problem: A 150mm concrete wall (density 2400 kg/m3) has surface density of 360 kg/m2. What is the TL at 500 Hz?

Solution: Surface density m = 0.15 x 2400 = 360 kg/m2\nTL (normal) = 20 log10(pi x 360 x 500 / (1.21 x 343))\n= 20 log10(565487 / 415)\n= 20 log10(1362.6)\n= 20 x 3.134 = 62.7 dB\nTL (field incidence) = 62.7 - 5 = 57.7 dB\nAt 1000 Hz: TL = 57.7 + 6 = 63.7 dB (6 dB increase per octave)

Result: TL at 500 Hz: 57.7 dB (field) | STC approximately 58 | Excellent sound insulation

Example 2: Drywall Partition Assessment

Problem: A single layer of 12.5mm gypsum board (surface density 9 kg/m2). What is the TL at 250 Hz and 1000 Hz?

Solution: At 250 Hz:\nTL = 20 log10(pi x 9 x 250 / (1.21 x 343)) - 5\n= 20 log10(7069 / 415) - 5\n= 20 log10(17.03) - 5\n= 24.6 - 5 = 19.6 dB\n\nAt 1000 Hz:\nTL = 20 log10(pi x 9 x 1000 / 415) - 5\n= 20 log10(68.1) - 5 = 36.7 - 5 = 31.7 dB

Result: TL at 250 Hz: 19.6 dB | TL at 1000 Hz: 31.7 dB | Poor isolation, needs improvement

Frequently Asked Questions

What is transmission loss (TL) and how is it measured in acoustics?

Transmission loss is a measure of how much sound energy a partition (wall, floor, window, or door) blocks, expressed in decibels (dB). It is defined as 10 times the log base 10 of the ratio of incident sound power to transmitted sound power: TL = 10 log10(Wi/Wt). A TL of 30 dB means only 1/1000 of the incident sound energy passes through the partition. TL depends on frequency, with most partitions providing less isolation at low frequencies and more at high frequencies. It is measured in laboratory conditions using two reverberation chambers separated by a test wall, following standards like ASTM E90 or ISO 10140. The measurement quantifies the intrinsic sound-blocking ability of the partition itself.

What is the difference between normal incidence and field incidence transmission loss?

Normal incidence TL assumes sound hits the partition perpendicularly (at zero degrees), which gives the maximum theoretical TL. Field incidence (also called random incidence) accounts for sound arriving from all directions simultaneously, which is more realistic for most practical situations. Field incidence TL is typically 5-6 dB lower than normal incidence because oblique sound waves at certain angles can more easily excite the partition into vibration, especially near the coincidence frequency. In laboratory measurements, a diffuse sound field in the source room provides approximately field incidence conditions. For practical design calculations, field incidence TL values are more appropriate because real rooms have sound coming from multiple directions and reflections.

What is the coincidence effect and how does it create a dip in transmission loss?

The coincidence effect (also called the critical frequency effect) occurs when the wavelength of a bending wave in the partition matches the projected wavelength of the incident sound wave along the partition surface. At this coincidence frequency, the partition vibrates very efficiently in response to the incoming sound, dramatically reducing its transmission loss. The coincidence frequency depends on the material stiffness, thickness, and density: thinner, stiffer, lighter panels have higher coincidence frequencies. For 10mm gypsum board, coincidence is around 3000 Hz. For 150mm concrete, it is around 100 Hz. Above the coincidence frequency, TL increases at about 9 dB per octave instead of the mass law 6 dB per octave, eventually recovering and exceeding the mass law prediction.

What is STC (Sound Transmission Class) and how does it relate to transmission loss?

Sound Transmission Class is a single-number rating that summarizes the sound insulation performance of a partition across the frequency range important for speech (125-4000 Hz). It is determined by fitting a standard reference contour to the measured TL values across 16 one-third octave bands, following ASTM E413. A higher STC number means better sound insulation. Typical STC values include: single pane window STC 26-28, standard interior wall (single stud, single layer drywall) STC 33-35, double stud wall with insulation STC 55-60, and concrete masonry walls STC 45-55. Building codes typically require STC 50 or higher between dwelling units in multi-family buildings. However, STC does not account for low-frequency sound below 125 Hz, which is increasingly problematic with home theaters and music systems.

What is the relationship between transmission loss and noise reduction in a real building?

Noise reduction (NR) is the actual difference in sound levels between two rooms separated by a partition, and it differs from TL because it depends on the receiving room acoustics and the partition area. NR = TL + 10 log10(A/S), where A is the total absorption in the receiving room (in sabins) and S is the partition area (in m2). If the receiving room is very reverberant (low absorption), the noise reduction will be less than the TL because transmitted sound builds up in the room. Conversely, a highly absorptive receiving room can provide noise reduction exceeding the TL value. Additionally, flanking transmission through floors, ceilings, and shared structures can bypass the partition entirely, limiting the achievable noise reduction regardless of the partition TL.

How do I interpret the result?

Results are displayed with a label and unit to help you understand the output. Many calculators include a short explanation or classification below the result (for example, a BMI category or risk level). Refer to the worked examples section on this page for real-world context.

References