Rockwell to Brinell Hardness Converter
Convert between Rockwell HRC, Brinell HB, and Vickers HV hardness scales for metals. Enter values for instant results with step-by-step formulas.
Formula
HB = f(HRC) based on ASTM E140 empirical tables
Hardness conversions use empirical relationships from ASTM E140 standard conversion tables. These are not exact mathematical formulas but rather experimentally determined correlations valid primarily for carbon and alloy steels. The conversions are approximations because different hardness tests measure different material responses.
Worked Examples
Example 1: Tool Steel Hardness Conversion
Problem: A tool steel is heat treated to 58 HRC. What are the equivalent Brinell and Vickers hardness values?
Solution: Using empirical conversion formulas:\nHB = -0.0743 x 58^2 + 12.673 x 58 - 123.5\nHB = -249.9 + 735.0 - 123.5 = 362 HB (approx)\n\nHV = -0.0352 x 58^2 + 9.284 x 58 - 10.5\nHV = -118.4 + 538.5 - 10.5 = 410 HV (approx)\n\nTensile strength estimate: 362 x 3.45 = 1249 MPa
Result: 58 HRC = ~362 HB = ~410 HV = ~1249 MPa tensile
Example 2: Casting Quality Verification
Problem: A steel casting tests at 250 HB. What is the approximate Rockwell C hardness?
Solution: Using reverse conversion:\nHRC = -0.000105 x 250^2 + 0.1869 x 250 - 28.45\nHRC = -6.56 + 46.73 - 28.45 = 11.72\n\nSince this is below 20 HRC, the Rockwell C scale is not ideal for this hardness level.\nRockwell B (HRB) would be more appropriate.\nApproximate tensile: 250 x 3.45 = 863 MPa
Result: 250 HB = ~23.5 HRC (borderline for C scale) = ~863 MPa tensile
Frequently Asked Questions
What is the Rockwell hardness scale and how is it measured?
The Rockwell hardness test measures the depth of penetration of an indenter under a large load compared to the penetration made by a preload. The Rockwell C scale (HRC) uses a diamond cone indenter with a 150 kg major load and is the most commonly used scale for testing hardened steels. The test involves applying a minor load of 10 kg to seat the indenter, then applying the major load of 150 kg, and measuring the additional depth of penetration. The hardness value is calculated from the depth measurement using a formula specific to each scale. Rockwell testing is fast, typically taking less than 15 seconds, and requires minimal surface preparation compared to other hardness test methods.
What is the Brinell hardness test and when should it be used?
The Brinell hardness test uses a hardened steel or tungsten carbide ball indenter pressed into the test material under a specified load, typically 3000 kgf for steels using a 10 mm ball. After the load is removed, the diameter of the resulting impression is measured using a microscope, and the Brinell hardness number (HB) is calculated by dividing the applied load by the surface area of the indentation. Brinell testing is particularly useful for materials with coarse or uneven microstructures such as castings, forgings, and rough surfaces where the larger indentation averages out local variations. The test is less suitable for very hard materials above approximately 650 HB because the ball indenter can deform and produce inaccurate results.
How accurate are hardness conversion calculations?
Hardness conversion calculations provide approximate equivalents because different tests measure fundamentally different material responses. Rockwell tests measure penetration depth while Brinell tests measure indentation diameter, and Vickers tests measure diagonal length of a square impression. The conversions in this tool are based on empirical relationships derived from ASTM E140 standard conversion tables for steel. Accuracy is typically within plus or minus 2 to 5 percent for carbon and alloy steels within the valid range. However, conversions become less reliable for non-ferrous metals, stainless steels, and materials with unusual work-hardening characteristics. For critical applications, always perform the actual hardness test in the required scale rather than relying solely on conversions.
What is the Vickers hardness scale and how does it relate to Rockwell and Brinell?
The Vickers hardness test uses a square-based diamond pyramid indenter with a 136-degree angle between opposite faces. The test can use any load from 1 gf to 120 kgf, making it versatile for both micro and macro hardness testing. Vickers hardness (HV) is calculated by dividing the applied force by the surface area of the indentation measured through the diagonals of the square impression. Unlike Rockwell and Brinell scales, the Vickers scale is continuous and does not require scale changes for different hardness ranges. Vickers numbers are roughly comparable to Brinell numbers below 300 HB, but the scales diverge at higher hardness values. Vickers testing is especially valuable for thin materials, surface hardness measurements, and weld heat-affected zone analysis.
Can I estimate tensile strength from hardness values?
Yes, there is a well-established empirical relationship between Brinell hardness and tensile strength for carbon and alloy steels. The approximate formula is Tensile Strength in MPa equals HB multiplied by 3.45, or in psi equals HB multiplied by 500. This relationship is reasonably accurate for steels with hardness between 120 and 450 HB. For example, a steel with 200 HB has an approximate tensile strength of 690 MPa (100 ksi). However, this correlation applies primarily to quenched and tempered carbon and alloy steels and should not be used for austenitic stainless steels, cast irons, non-ferrous metals, or precipitation-hardened alloys. For these materials, the relationship between hardness and tensile strength follows different correlations.
What factors affect hardness test results and conversions?
Multiple factors influence hardness test results beyond the inherent material hardness. Surface roughness affects indentation measurement accuracy, particularly for Brinell and Vickers tests where the impression dimensions are optically measured. Specimen thickness must be sufficient to prevent the indentation from being influenced by the support surface, generally requiring at least ten times the indentation depth. Test location matters because edges and previous indentations create stress fields that distort results. Temperature affects material behavior, with most standards requiring testing at room temperature. Internal residual stresses from machining, welding, or heat treatment can alter local hardness readings. Proper surface preparation, correct loading procedures, and appropriate indenter condition are all essential for reliable measurements.